    70-1165

    Main Features
    • Display : 12-inch HD color
    • Networking : Wired and wireless(optional)
    • Working time : 5-6hours(Built-in capacity battery)
    • Alarm : sound, light, message human voice
    • Working Modes : Monitoring, Surgery and Diagnosis
    • Real-time ST analysis, Pacemaker detection, Arrhythmia analysis
    • USB interfaces support:
      •  Easy software upgrade and data transfer
      •  Multi-display modes suitable for different applications
      •  Unique accessory management cabinet

    Technical Specification
    ECG

    • Lead Mode : 5 Leads (I, II, III, AVR, AVL, AVF, V)
    • ST measurement range : -2.0~+2.0 mV
    • Gain : 2.5mm/mV, 5.0mm/mV, 10mm/mV 20mm/mV
    • Heart Rate : 15-300 BPM (Adult), 15-350 BPM (Neonatal)
    • Resolution : 1BPM
    • Accuracy : ±1%
    • Sensitivity : >200uV(Peak to peak)
    • Accuracy : -0.8mV-+0.8mV: ±0.02mV or ±10% (which is greater)
    • Other Range : unspecified.
    • Sweep speed : 12.5 mm/s, 25mm/s, 50mm/s.
    • Bandwidth
      •  Diagnostic : 0.05-130 Hz
      •  Monitor:0.5~40 Hz
      •  Surgery:1-20 Hz
    NIBP
    • Method : Oscillation Method
    • Measure mode : Manual, Auto, STAT
    • Unit : mmHg, kPa
    • Measure and alarm range:
          • Adult Mode
               •  SYS :40 ~ 270 mmHg
               •  DIA :10 ~ 215 mmHg
               •  MEAN :20 ~ 235 mmHg
          • Pediatric Mode
             •  SYS :40 ~ 200 mmHg
             •  DIA :10 ~ 150 mmHg
             •  MEAN :20 ~ 165 mmHg
          •  Neonatal Mode
             •  SYS :40 ~135 mmHg
             •  DIA :10 ~100 mmHg
             •  MEAN :20 ~110 mmHg
    • Resolution:1mmHg
    • Accuracy:±5mm Hg
    SpO2
    • Measuring Range : 0-100%
    • Resolution : 1%
    • Accuracy : 70%-100% (±2%)
    • Pulse Rate : 20-300 BPM
    • Resolution : 1 BPM
    • Accuracy : ±3 BPM
    TEMP
    • Measure and Alarm Range : 0-50°C
    • Resolution : 0.1°C
    • Accuracy : ±0.1°C
    • Standard Parameters : ECG, RESP, TEMP,NIBP, SpO2, PR
    RESP
    • Method : Impedance between RA-LL
    • Measurement Range:
    • Adult:2-120 BrPM
    • Neonatal/Pediatric:7-150 BrPM
    • Accuracy : ±2 BrPM
    Optional Parameters
    • Recorder(Printer)
    • Multi-Gas module
    • Central monitoring system
    • Dual IBP
    • Mainstream/sidestream EtcO2 module
    • Touch screen
    • Wireless network connection
    • MASIMO/Nellcor SpO2;
    • CSM/Cerebaral state monitor module
    • 12 leads ECG
    Standard Configuration
    • Main Unit : 1 Pc.
    • 5-lead ECG cable : 1 Pc.
    • Disposable ECG Electrode : 5 Pcs.
    • Adult SpO2 probe : 1 Pc.
    • Adult NIBP cuff : 1 Pc.
    • NIBP extension tube : 1 Pc.
    • Temperature probe : 1 Pc.
    • Power Cable : 1 Pc.
    • User Manual : 1 Pc.

     

    *Customizable as per requirement.