Model No.: 56-0117, Neonatal Phototherapy Unit

|
- Mobile Stand with height adjustment facility along with easy swiveling of source box and adjustable light intensity in the range of 420nm to 480nm wave length
- Unit can be used along with Infant Care Trolley, Radiant Warmer and Incubator
- 4 Special Blue CFL Tubes of 18 W each
- 2 Daylight CFL Tubes of 18 W each
- Tubes are protected by grill
- Digital Timer for Lamp Usage Hour and Patient Exposure
- Irradiance at skin level, up to: 25 μW/cm2/nm
- Source Cooling fan
- Mirror Coated Reflector
- Stand movable on four anti-static castors, two with brakes
- Height adjustable from 125 to 170cm
- Power Supply: 220V/50Hz
- Power Consumption: 250W
- Dimensions: 70 x 80 x 160 cm
- Weight : 20Kg
|
Model No.: 56-0121, Phototherapy Unit, Single Head, with Counter, Height and Angle Adjustable

|
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate . This has been achieved by exposing the infant to bright light (approximately 4.5 micro watts/sq cm/nm) in the range of 420-480 nm wave length by use of conventional phototherapy unit has been one of most important focus in the field of neonatalogy for many years. In order to remove the limitation of fluorescent and CFL tubes, we have utilised long lasting, durable, more efficient and cost effective LEDs with more than double the flux as against what is radiated from conventional, fluorescent and CFL, for jaundice treatment.
Technical Specifications:
Parameter:
- LED 9-12 hi power LEDs(blue)
- Irradiance>42mw/cm2/nmat30cm
- Light source lifetime minimum 25,000hrs.
- Less than 10% change in illumination after 25,000hrs(irradiance)
|
- Wavelength 420-480 nm
- Variation in intensity for 6 hours<10%
- Effective area 50 cm X 30 cm.
- Phototherapy irradiance meter
- Measures the output of conventional tube-based neonatal phototherapy devices
- Portable handheld with carry strap
- Band pass filter, transmission only from 425 to 475 nm
- Total block for infrared and ultraviolet light
- Detector range, 364: 1 to 100 uW/cm2/nm
- Minimal graduation: 1 uW/cm2/nm
- Accuracy: ± 3 % of full scale
- Automatic zero setting between measurements
- Measuring time, 364: 5 sec
- Large LCD shows irradiance measurement in uW/cm2/nm
- Display also reports on system malfunction and battery status
- On switch and auto-off
- Power requirements: 2 batteries 1.5 V, AAA / LR3
- Power consumption, 364 : 1 W (battery life, 364, 72 hours measuring time)
Material: Reinforced plastic
Electrical: Input voltage: 100-240 V, 50-60Hz
Dimensions:
- Led box
- Front: 18" (L)x 10" (w)x3"(H) Backside: 18"x 8.5"x3" Height(adjustable)
- Min :1230 mm
- Max :1600mm
- Length-800mm
- Width-720mm
- Double Surface Phototherapy Unit: It is a combination of over head phototherapy Unit and undersurface Phototherapy with Baby Bassinet.
Supplied with:
- 1 x Protective cap for light sensor
- 1 x Set of batteries 1.5 V, AAA / LR3 (separately packed)
- 1 x Storage and transportation pouch