Fill the details to complete enquire now
Features
TECHNICAL SPECIFICATIONS | |||
---|---|---|---|
Temperature Control | Air, Skin & Humidity Control | ||
Alarm | Sensor failure alarm | Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power | |
Temperature alarm | Alarm with audible and visual when displayed temperature approach above the set temp. | ||
Deviation alarm | After temperature equilibrium, alarm with audible & visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C | ||
Power failure alarm | Alarm with audible and visual when power failure | ||
Temperature Control Range & Correlative Parameters | Air Temperature Control Range | 25°C 〜40°C | |
Temperature override mode to | 20°C~39°C | ||
Skin Temp Control Range | 30°C~37°C | ||
Temperature override mode to | 30°C~38°C | ||
Skin temp sensor accuracy | ≤0.3°C | ||
Temperature fluctuation | ≤0.5°C | ||
Mattress temperature uniformity | ≤0.8°C | ||
Temperature Rise Time | ≤30min | ||
Temperature Variability | ±0.5°C | ||
Temperature Uniformity | ≤1°C | ||
Phototherapy | Wave lenght | 420nm - 480 nm | |
LED Life | Minimum 25, 000 hrs. | ||
Effective Area | 50cm x 30cm | ||
Irradiance | >42mw/cm2/nm | ||
Hood | Wall Type | Single Wall / Double Wall/ Triple Wall | |
Operating Ports | 6 (2 Iris ports) 2 Hand Port 1 Oxygen Inlet port | ||
Tubing grommets | 4 | ||
Noise Level Within Hood Environment | ≤55dB(Environment noise below 45dB) | ||
Carbon Dioxide (Co2) Level within the hood | Less than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress | ||
Air Velocity Over Mattress | less than 0.3m/s | ||
Infant Bed Max Load | 10kg | ||
Transfusion Shelf Max Load | 2kg | ||
Inclination | Able to tilt ± 10 degrees | ||
Front access panel | 826×310 mm approx. | ||
Mattress Tray Size | 630×360 mm approx. | ||
Factory Default Settings | Temperature Control Mode / Air Temperature Mode | ||
Air Set Temperature: 32°C | |||
Temperature Units:°C | |||
RS 232 Connector (Optional) | Yes | ||
X ray Tray | The bassinet have facility for xray cassette | ||
Cabinet Max load | 6kg | ||
Environment Requirement | Environment Temperature | Operation Temperature Range | +20°C~+30°C |
Store Temperature Range | - 40°C~+55°C | ||
Environment Humidity | Operation Humidity Range | 30%~75% | |
Store Humidity Range | 10%~100% | ||
Atmospheric Pressure Range | 700hPa~1060hPa | ||
Power | Power Supply | 180 V to 240 V, 50 / 60Hz | |
Power Input | ≤400VA | ||
Battery | Yes | ||
Accessories | Monitoring shelf | ||
Telescopic iv stand | |||
Air Probe, Skin Probe & Humidity Probe | |||
Optional | Oxygen Delivery System | ||
Electric Slow Section |